4.0

Out of 12 Ratings

Owner's of the First Alert Carbon Monoxide Alarm CO600 gave it a score of 4.0 out of 5. Here's how the scores stacked up:
  • Reliability

    4.0 out of 5
  • Durability

    4.08 out of 5
  • Maintenance

    3.91 out of 5
  • Performance

    3.8 out of 5
  • Ease of Use

    4.45 out of 5
of 6
 
LIMITED WARRANTY
BRK Brands, Inc. ("BRK") the maker of First Alert
®
brand products, warrants that for a period of 5 years from the date of purchase, this product
will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product
found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component. If the
product is no longer available, replacement may be made with a similar product of equal or greater value This is your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales
receipt. Proof of purchase is required to obtain warranty performance. BRK dealers, service centers, or retail
stores selling BRK products do
not have the right to alter, modify or any way change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use
on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an
authorized service center. Further, the warranty does not cover acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that
are included with this unit.
BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the
extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the
duration of the above warranty. Some states, provinces, or jurisdictions do not allow the exclusion or limitation of
incidental or consequential
damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives
you specific legal rights, and you may also have other rights that vary from state to state, or province to province.
How to Obtain Warranty Service
Service: If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs
Division at 1-800-323-9005, 7:30 AM to 5:00 PM, Central Standard Time, Monday through Friday. To assist in serving you, please have the
model number and date of purchase available when calling.
For Warranty Service return to: BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906
6
TROUBLESHOOTING GUIDE
PROBLEM... ...DLUOHS UOY...SNAEM SIHT
Red light is OFF. Unit will not alarm when you
press the Test/Silence button.
CO Alarms may not be plugged all the way in, or
is not receiving power.
Gently push unit all the way into outlet. Make
sure it is not plugged into an outlet controlled by
a switch.
The light flashes (RED) and the horn sounds 3
quick “chirps” every minute.
MALFUNCTION SIGNAL. CO Alarm needs to be
replaced.
Make sure unit is plugged in securely.
CO Alarms under warranty should be returned
to manufacturer for replacement. See “Limited
Warranty” for details.
CO Alarm goes back into alarm 4 minutes after
you press the Test/Silence button.
CO levels indicate a potentially dangerous
situation.
IF YOU ARE FEELING SYMPTOMS OF CO
POISONING, EVACUATE your home and call 911
or the Fire Department. If not, press the Test/
Silence button again and keep ventilating your
home.
CO Alarm sounds frequently even though no high
levels of CO are revealed in an investigation.
The CO Alarm may be improperly located.
Refer to “Where to Install CO Alarms.”
Relocate your Alarm. If frequent alarms continue,
have home rechecked for potential CO problems.
You may be experiencing an intermittent CO
problem.
If you have any questions that cannot be answered by reading this manual, call Consumer Affairs at 1-800-323-9005.
First Alert
®
is a registered trademark of the First Alert Trust.
Printed in Mexico M08-0152-002 S 07/07
For your records, please record:
Date Purchased: __________________
Where Purchased: _______________________
Date Installed: ____________/____________Month/Year
Replacement date is five years after installation:
_____________/____________Month/Year
NOTE: End of Life Signal — Once the unit reaches the end of
its lifecycle, the MALFUNCTION SIGNAL will sound once a
minute to indicate the need to immediately replace the Alarm.