0

Out of 0 Ratings

Owner's of the Furuno TV Converter Box NMEA Data Converter gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 13
 
5
Turning Power On
No operation is required for the user to turn the power on. The power is
supplied by Furuno CAN bus line. The Power LED (yellow) flashes when the
data converter is powered.
Power LED
Input/Output Comparing
Furuno CAN bus NMEA0183
Some Furuno CAN bus PGN output a number of NMEA0183 sentences.
NP means “nonperiodic”.
ID means “Message ID”.
Sending Cycle
Furuno CAN bus
Input
NMEA0183
Output
Normal
High
Speed
AIS Zeus
65280
Heave
[Proprietary PGN]
PFEChve × 100ms × ×
RMC 1s, 2s* 1s 1s 1s, 2s*
126992 System Time
ZDA 1s 1s × 1s
127245 Rudder RSA × 100ms × ×
HDG 1s 100ms × 1s
HDT 1s 100ms × 1s
RMC 1s, 2s* 1s 1s 1s, 2s*
127250 Vessel Heading
VHW 1s 1s × 1s
127251 Rate of Turn ROT × 100ms × ×
127257 Attitude PFECatt × 100ms × ×
HDG 1s 100ms × 1s
127258 Magnetic Variation
RMC 1s, 2s* 1s 1s 1s, 2s*
RMC 1s, 2s* 1s 1s 1s, 2s*
VHW 1s 1s × 1s
128259 Speed Through Water
VTG 1s 1s × 1s
128267 Water Depth DPT 1s 1s × 1s
128520 Tracked Target Data TTM × NP NP ×
RMC 1s, 2s* 1s 1s 1s, 2s*
129026
COG & SOG, Rapid
Update
VTG 1s 1s × 1s