28
Ensure the Safety Reversing Sensors are aligned
2
The sensors can be aligned by loosening
the wing nuts, aligning the sensors, and
tightening the wing nuts.
2.1 Check to make sure the LEDs in both sensors are glowing steadily. The LEDs in both sensors will glow steadily if they are aligned
and wired correctly.
IF THE AMBER LED ON THE SENDING SENSOR IS NOT GLOWING:
IF THE GREEN LED ON THE RECEIVING SENSOR IS NOT GLOWING:
Green LED
SENDING SENSOR RECEIVING SENSOR
Amber LED
Make sure there is
power to the garage
door opener.
Make sure the
sensor wire is not
shorted/broken.
Make sure the sensors are aligned.
The door will not close if the sensors have
not been installed and aligned correctly.
When the light beam is obstructed or
misaligned while the door is closing, the
door will reverse and the garage door
opener lights will fl ash ten times. If the door
is already open, it will not close.
RED
WHITE
WHITE
GREY
Make sure the sensor has been wired
correctly: white wires to white terminal and
white/black wires to grey terminal.
Make sure the sensor wire is
not shorted/broken.
If the receiving sensor is in
direct sunlight, switch it with
sending sensor so it is on the
opposite side of the door.
(invisible light beam)
Power
Ensure the Door Control is wired correctly
3
If the door control has been installed and wired correctly, a message will display on the Smart Control Panel screen or the command LED on the Motion-Detecting Control Panel will blink.