9
Pilot Sequence of Operation
PILOT OPERATION
• Gas Pressure 11˝ W.C. to control is necessary. Set with two gas appliances running.
• Gas Control supplies gas to pilot orifice when control ON/OFF pilot knob is held at pilot position.
Pilot Orifice meters gas to heat thermocouple. Flame should be high enough to engulf the
thermocouple.
Thermocouple generates millivoltage to the gas control’s magnet assembly.
Magnet when it receives 12 millivolts or more it allows gas to flow freely to pilot without
holding pilot knob.
E.C.O. passes millivolts through the gas control and back to thermocouple. Trips
permanently open if water temperature exceeds 190°F.
MAIN BURNER OPERATION
Gas Control supplies gas to main burner when control knob is set to “ON” position and the
temperature lever is set to desired temperature after pilot is lit.
Main Burner Orifice meters gas through burner tube.
Main Burner pilot ignites gas when it reaches end of this tube. Flame height adjusted by sliding air
shutter. Ideal setting is 1/4 way open (.20˝). Flame should be primarily blue with
a trace of yellow.
Temperature Knob setting of knob determines burner cycle and water temperature. Temperature range is
70°F - 140°F.
Pilot Flame
Thermocouple
ON/OFF Pilot Knob
Air Shutter
ONE SHOT
E.C.O. 190°
Gas Inlet
11" W.C.
Pressure
JADE CONTROL SYSTEM
Temperature Lever
Pilot Orifice (inside)