17
Dialing Time-out
Dialing Time-out can be enabled or disabled and by default is enabled.When enabled, the dialing time-out starts as
soon as the unit becomes active. The dialing time-out lasts 15 seconds and is reset with every DTMF tone until the
string is complete. If no DTMF is detected within those 15 seconds, there will be an error tone.This feature is only
valid in RUN mode, not PROGRAM mode.When dialing time-out is disabled, the unit will follow the default timer.
DTMF Block
If enabled, DTMF Block suppresses DTMF keys so that only a short portion of the tone can be heard over the
speakers during a page. Disabling DTMF Block allows a user to pass DTMF keys to external equipment connected
to the zone outputs during a page.
Trunk Disconnect
The UTI312 includes a Trunk Disconnect feature.The purpose of the Trunk Disconnect feature is to release the
UTI312 from the trunk port in the event a user does not hang up the phone properly after making a page. If the
UTI312 does not detect voice for the interface VOX time-out period, or if the interface default timer expires, the
UTI312 will attempt to release from the trunk by momentarily interrupting the talk battery.When using the Trunk
Disconnect feature, the PBX must have disconnect supervision available on the trunk port being used.The Trunk
Disconnect feature is disabled by default.
Timers
Default Timer
If the UTI312 is connected to a PBX station port, or a trunk port with the Trunk Disconnect feature enabled, you
can set the maximum page duration (default timer).The factory setting for this timer is 30 seconds and can be
adjusted in 10 second increments up to 990 seconds.This timer can be inhibited. See System Programming for more
information on setting or inhibiting the Default Timer.
VOX Timer
If the UTI312 is connected to a station port, page port VOX, or trunk port with the Trunk Disconnect feature
enabled, you can set the time duration for the maximum silence duration time-out.The factory setting is 6 seconds
and can be adjusted in 1 second increments up to 9 seconds.This timer can be inhibited. See System Programming
for more information on setting or inhibiting the VOX Timer.
Calling Party Controlled Disconnect
When in station mode, the UTI312 will immediately disconnect when it detects a CPC (calling party control) signal.
A CPC signal is a loss of loop current for greater than 300mS. It is typically issued by the PBX or CO immediately
after the calling party hangs up, but can be delayed for up to 10 seconds depending on the equipment issuing the
signal.The UTI312's detection and disconnection is not defeatable and is the only way to disconnect from a station
port if both the Default and VOX Timers are inhibited.
Setup Tone
This tone can be activated only when the system is in Program mode (set with Run/Program switch). It is an all-call
interrupted tone that can be used by the installer to check speaker operation and to set the operational level of
the speakers.
Note:The volume level of this tone is controlled by the Tone Level Control.
Reset Default Values
A feature code is available to reset the UTI312 system to the original factory default values.Wait for a confirmation
tone before hanging up.This will not clear any flexible dialing numbers that have been programmed into the system.
Priority Levels
The following list indicates the priority level operation of the UTI312 features.
Highest Override
Tone Trigger 1
Tone Trigger 2
Paging
Night Ring
Lowest Background Music