Tone Zone Groups
In addition to paging zone groups,there are five additional zone groups,each with an associated tonal function.These
are Override zone group, Night Ring zone group,Tone Trigger 1 zone group,Tone Trigger 2 zone group, and Code
Call zone group. By default, these zone groups are set to all zones.
Each is programmed in the same manner as the paging zone groups,only with a different feature code. For example,
to program zones to the Tone Trigger 1 zone group,dial the Tone Trigger 1 zone group feature code (*91), followed
by the zone numbers to be included in the zone group, followed by the # key to store the data.
To return these zone groups to All-Call, dial their respective feature code followed by 00# (*9700#).
To clear zones from these zone groups, dial the feature code for that particular
zone group followed by the # sign. For example, to clear all zones from Tone
Trigger 1 zone group, dial *91#.
What differentiates these zone groups from the paging zone groups is the tone
associated with them. The tone for each of these zone groups can also be
programmed along with the zones. For example, to program Tone Trigger 1 for
zone 1, zone 3, zone 5, and zone 7 with the chime follow contact tone (feature
code 029), dial *9101030507#029#.
For each particular zone group’s default settings and options, refer to the Feature Codes and Defaults table on
pages 23-26.
Code Calling
Code calling triggers a series of chime tones to the Code Call zone group.There are two types of code calling:
pattern and echo.
Pattern Code Call
Pattern code calling sounds a factory-set pattern of chime tones in response to a DTMF selection by the caller.
There are 10 patterns available.To program the Code Call zone group for pattern code calling, dial feature code
041 followed by the # key.
Echo Code Call
Echo code calling sounds chime tones that correspond to a 2-digit entry made by the caller with each digit
representing the number of chimes.To program the Code Call zone group for echo code calling, dial feature code
042 followed by the # key.
Code Call Playback
By default, code calling triggers a series of chime tones to a zone or zone group one time (Code Call 1 Play).Code
calling can be programmed to playback the series of chime tones once (Code Call 1 Repeat) or twice (Code Call
2 Repeat) for a total of three executions.To program code calling for 1 Repeat or 2 Repeat, dial the feature code
(044 or 045) followed by the # key. Ex.: 044# for Code Call 1 Repeat.
The code call feature can be enabled and disabled without losing any of the programmed data associated with it.
DTMF Block
DTMF Block, to suppress DTMF tone pass-through, can be enabled (feature code 068) or disabled (feature code
069).
Timers
Default Timer
To change the default timer, enter the feature code 050 and the new 2-digit number corresponding to the time
desired followed by the # key.The 2-digit number represents default time in multiples of 10 seconds. (Example: 03
= 30 seconds; 12 = 120 seconds.) Ex.:05003# for 30 seconds. If you wish to inhibit the default timer,enter "00" for
the time data.
VOX Timer
To set the time duration for the VOX time-out, enter the feature code 051 followed by a single digit from 1 to 9,
corresponding to 1 to 9 seconds, followed by the # key. Ex.: 0515# for 5 seconds.To inhibit the timer, enter the
Feature Code followed by "0".
Note: If both the default and VOX timers are inhibited, the only way to release the UTI312 from a station line is through the
use of a Calling Party Control (CPC) pulse of 300 ms or longer.